5.9
Conductivity
What is conductivity and
why is it important?
Conductivity is a measure of the
ability of water to pass an
electrical current. Conductivity
in water is affected by the
presence of inorganic dissolved
solids such as chloride, nitrate,
sulfate, and phosphate anions
(ions that carry a negative
charge) or sodium, magnesium,
calcium, iron, and aluminum
cations (ions that carry a
positive charge). Organic
compounds like oil, phenol,
alcohol, and sugar do not
conduct electrical current very
well and therefore have a low
conductivity when in water.
Conductivity is also affected by
temperature: the warmer the
water, the higher the
conductivity. For this reason,
conductivity is reported as
conductivity at 25 degrees
Celsius (25 C).
Conductivity in streams and
rivers is affected primarily by
the geology of the area through
which the water flows. Streams
that run through areas with
granite bedrock tend to have
lower conductivity because
granite is composed of more
inert materials that do not ionize
(dissolve into ionic components)
when washed into the water.
On the other hand, streams that
run through areas with clay soils
tend to have higher conductivity
because of the presence of
materials that ionize when
washed into the water. Ground
water inflows can have the same
effects depending on the
bedrock they flow through.
Discharges to streams can
change the conductivity
depending on their make-up. A
failing sewage system would
raise the conductivity because
of the presence of chloride,
phosphate, and nitrate; an oil
spill would lower the
conductivity.
The basic unit of measurement of conductivity is the mho or
siemens. Conductivity is measured in micromhos per centimeter (µmhos/cm) or
microsiemens per centimeter (µs/cm). Distilled water has a conductivity in the
range of 0.5 to 3 µmhos/cm. The conductivity of rivers in the United States
generally ranges from 50 to 1500 µmhos/cm. Studies of inland fresh waters
indicate that streams supporting good mixed fisheries have a range between 150
and 500 µhos/cm. Conductivity outside this range could indicate that the
water is not suitable for certain species of fish or macroinvertebrates. Industrial
waters can range as high as 10,000 µmhos/cm.
Sampling and equipment Considerations
Conductivity is useful as a general measure of stream water quality. Each stream tends to have a relatively constant range of conductivity that, once established, can be used as a baseline for comparison with regular conductivity measurements. Significant
changes in conductivity could then be an indicator that a discharge or some other source of pollution has entered a stream.
Conductivity is measured with a probe and a meter. Voltage is applied
between two electrodes in a probe immersed in the sample water. The drop in
voltage caused by the resistance of the water is used to calculate the conductivity
per centimeter. The meter converts the probe measurement to micromhos
per centimeter and displays the result for the user. NOTE: Some conductivity
meters can also be used to test for total dissolved solids and salinity. The total
dissolved solids concentration in milligrams per liter (mg/L) can also be
calculated by multiplying the conductivity result by a factor between 0.55
and 0.9, which is empirically determined (see Standard Methods #2510, APHA
1992).
Suitable conductivity meters cost about $350. Meters in this price range should also measure
temperature and automatically compensate for temperature in the conductivity reading.
Conductivity can be measured in the field or the lab. In most cases, it is probably better if the
samples are collected in the field and taken to a lab for testing. In this way several teams of
volunteers can collect samples simultaneously. If it is important to test in the field, meters
designed for field use can be obtained for around the same cost mentioned above.
If samples will be collected in the field for later measurement, the sample bottle should be a
glass or polyethylene bottle that has been washed in phosphate-free detergent and rinsed
thoroughly with both tap and distilled water. Factory-prepared Whirl-pak® bags may be used.
How to sample
The procedures for collecting samples and analyzing conductivity consist of the following tasks:
TASK 1 Prepare the sample containers
If factory-sealed, disposable Whirl-pak® bags are used for sampling, no preparation is needed.
Reused sample containers (and all glassware used in this procedure) must be cleaned before the
first run and after each sampling run by following Method A as described in MEthod A in Table 1 in Chapter 5 - Water Quality Conditions.
TASK 2 Prepare before leaving for the sampling site
Refer to section 2.3 - Safety Considerations for details on confirming sampling date and time, safety considerations,
checking supplies, and checking weather and directions. In addition to the standard sampling
equipment and apparel, when sampling for conductivity, include the following equipment:
- Conductivity meter and probe (if testing conductivity in the field)
- Conductivity standard appropriate for the range typical of the stream
- Data sheet for conductivity to record results
Be sure to let someone know where you are going and when you expect to return.
TASK 3 Collect the sample (if samples will be tested in the lab)
Refer to Task 2 in Chapter 5 - Water Quality Conditions for details on how to collect water samples using screw-cap bottles or Whirl-pak® bags.
TASK 4 Analyze the sample (field or lab)
The following procedure applies to field or lab use of the conductivity meter.
- Prepare the conductivity meter for use according to the manufacturer's directions.
- Use a conductivity standard solution (usually potassium chloride or sodium chloride) to calibrate the meter for the range that you will be measuring. The manufacturer's directions should describe the preparation procedures for the standard solutio
n.
- Rinse the probe with distilled or deionized water.
- Select the appropriate range beginning with the highest range and working down. Read the conductivity of the water sample. If the reading is in the lower 10 percent of the range, switch to the next lower range. If the conductivity of the sample ex
ceeds the range of the instrument, you may dilute the sample. Be sure to perform the dilution according to the manufacturer's directions because the dilution might not have a simple linear relationship to the conductivity.
- Rinse the probe with distilled or deionized water and repeat step 4 until finished.
TASK 5 Return the samples and the field data sheets to the lab/drop-off point.
Samples that are sent to a lab for conductivity analysis must be tested within 28 days of collection. Keep the samples on ice or refrigerated.
References
APHA. 1992. Standard methods for the examination of water and wastewater. 18th ed. American Public Health Association, Washington, DC.
Hach Company. 1992. Hach water analysis handbook. 2nd ed. Loveland, CO.
Mississippi Headwaters River Watch. 1991. Water quality procedures. Mississippi Headwaters Board. March.