| DICHLOROMONOFLUOROMETHANE | ICSC: 1106 |
|
Fluorodichloromethane Fluorocarbon 21 Refrigerant 21 (cylinder) CHCl2F Molecular mass: 102.9
CAS # 75-43-4RTECS # PA8400000 ICSC # 1106 UN # 1029 |
|
TYPES OF HAZARD/ EXPOSURE |
ACUTE HAZARDS/ SYMPTOMS |
PREVENTION |
FIRST AID/ FIRE FIGHTING |
| FIRE |
Not combustible.
Gives off irritating or toxic fumes (or gases) in a fire.
|
|
In case of fire in the surroundings: all extinguishing agents allowed.
|
| EXPLOSION |
|
|
In case of fire: keep cylinder cool by spraying with water.
|
| EXPOSURE |
|
STRICT HYGIENE!
|
|
|
|
Drowsiness.
Unconsciousness.
|
Ventilation, local exhaust, or breathing protection.
|
Fresh air, rest.
Artificial respiration if indicated.
Refer for medical attention.
|
|
|
ON CONTACT WITH LIQUID: FROSTBITE.
|
Cold-insulating gloves.
Protective clothing.
|
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes.
Refer for medical attention.
|
|
|
|
Safety goggles
or eye protection in combination with breathing protection.
|
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.
|
|
|
|
Do not eat, drink, or smoke during work.
|
|
| SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
|
Ventilation.
NEVER direct water jet on liquid.
Do NOT let this chemical enter the environment
(extra personal protection: self-contained breathing apparatus).
|
Fireproof if in building.
Separated from
strong acids,
chemically active metals.
Cool.
Keep in a well-ventilated room.
|
UN Hazard Class: 2.2 |
||
| SEE IMPORTANT INFORMATION ON BACK | ||||
|
||||
|
||||||||||||||||||||||||||||||||
| DICHLOROMONOFLUOROMETHANE | ICSC: 1106 |
|
I M P O R T A N T D A T A |
| |||
|
PHYSICAL PROPERTIES |
| |||
|
ENVIRONMENTAL DATA |
This substance may be hazardous to the environment; special attention should be given to ozone layer.
|
|||
| NOTES | ||||
|
Specific treatment is necessary in case of poisoning with this substance; the appropriate means with instructions must be available.
High concentrations in the air cause a deficiency of oxygen with the risk of unconsciousness or death.
Check oxygen content before entering area.
Do NOT use in the vicinity of a fire or a hot surface, or during welding.
Turn leaking cylinder with the leak up to prevent escape of gas in liquid state.
Freon 21, Genetron 21, Arcton 7 and Algofrene type 5 are trade names.
|
||||