| ACETYLENE | ICSC: 0089 |
|
Ethine Ethyne (cylinder) C2H2 Molecular mass: 26.0
CAS # 74-86-2RTECS # AO9600000 ICSC # 0089 UN # 1001 (dissolved) EC # 601-015-00-0 |
|
TYPES OF HAZARD/ EXPOSURE |
ACUTE HAZARDS/ SYMPTOMS |
PREVENTION |
FIRST AID/ FIRE FIGHTING |
| FIRE |
Extremely flammable.
|
NO open flames, NO sparks, and NO smoking.
|
Shut off supply; if not possible and no risk to surroundings, let the fire burn itself out; in other cases extinguish with
powder, carbon dioxide.
|
| EXPLOSION |
Gas/air mixtures are explosive.
|
Closed system, ventilation, explosion-proof electrical equipment and lighting.
Prevent build-up of electrostatic charges (e.g., by grounding).
Use reduced-sparking handtools.
Use flame arrester to prevent flash-back from burner to cylinder.
|
In case of fire: keep cylinder cool by spraying with water.
|
| EXPOSURE |
|
|
|
|
|
Dizziness.
Dullness.
|
Ventilation, local exhaust, or breathing protection.
|
Fresh air, rest.
Refer for medical attention.
|
|
|
ON CONTACT WITH LIQUID: FROSTBITE.
|
Cold-insulating gloves.
|
Rinse with plenty of water, do NOT remove clothes.
|
|
|
|
Safety goggles
or face shield.
|
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.
|
|
|
|
Do not eat, drink, or smoke during work.
|
|
| SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
|
Evacuate danger area!
Consult an expert!
Ventilation
(extra personal protection: self-contained breathing apparatus).
|
Fireproof.
Separated from: see Chemical Dangers.
Cool.
|
Special insulated cylinder.
F+ symbol R: 5-6-12 S: 9-16-33 UN Haz Class: 2.1 |
||
| SEE IMPORTANT INFORMATION ON BACK | ||||
|
||||
|
||||||||||||||||||||||||||||||||
| ACETYLENE | ICSC: 0089 |
|
I M P O R T A N T D A T A |
| |||
|
PHYSICAL PROPERTIES |
| |||
|
ENVIRONMENTAL DATA |
|
|||
| NOTES | ||||
Piping material for this gas must not contain over 63% of copper.
Check oxygen content before entering area.
After use for welding, turn valve off; regularly check tubing, etc., and test for leaks with soap and water.
|
||||
| ADDITIONAL INFORMATION | |||||
|
|
|
||||
|
|||||
|